127A
Legacyt Line Air Conditioner
with Puronr Refrigerant
1--1/2 To 5 Nominal Tons (Sizes 018 to 060)
Installation Instructions
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Use quenching cloth for brazing operations.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions included in
literature and attached to the unit. Consult local building codes and
current editions of the National Electrical Code ( NEC ) NFPA 70.
In Canada, refer to current editions of the Canadian electrical code
CSA 22.1.
Recognize safety information. This is the safety--alert symbol
When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury. Understand
these signal words; DANGER, WARNING, and CAUTION. These
words are used with the safety--alert symbol. DANGER identifies
the most serious hazards which will result in severe personal injury
or death. WARNING signifies hazards which could result in
personal injury or death. CAUTION is used to identify unsafe
practices which would result in minor personal injury or product
and property damage. NOTE is used to highlight suggestions
which will result in enhanced installation, reliability, or operation.
!
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position.
There may be more than 1 disconnect switch. Lock out and
tag switch with a suitable warning label.
INSTALLATION INSTRUCTIONS
NOTE: In some cases noise in the living area has been traced to
gas pulsations from improper installation of equipment.
1. Locate unit away from windows, patios, decks, etc. where
unit operation sound may disturb customer.
2. Ensure that vapor and liquid tube diameters are appropriate
for unit capacity.
3. Run refrigerant tubes as directly as possible by avoiding un-
necessary turns and bends.
4. Leave some slack between structure and unit to absorb vi-
bration.
5. When passing refrigerant tubes through the wall, seal open-
ing with RTV or other pliable silicon--based caulk. (See Fig.
1.)
6. Avoid direct tubing contact with water pipes, duct work,
floor joists, wall studs, floors, and walls.
7. Do not suspend refrigerant tubing from joists and studs with
a rigid wire or strap which comes in direct contact with
tubing.(See Fig. 1.)
8. Ensure that tubing insulation is pliable and completely sur-
rounds vapor tube.
9. When necessary, use hanger straps which are 1 in. (25.4
mm) wide and conform to shape of tubing insulation. (See
Fig. 1.)
10. Isolate hanger straps from insulation by using metal sleeves
bent to conform to shape of insulation.
INSULATION
VAPOR TUBE
LIQUID TUBE
OUTDOOR WALL
INDOOR WALL
LIQUID TUBE
VAPOR TUBE
INSULATION
CAULK
Avoid
contact
between
tubing
and
structure
NOTE:
THROUGH THE WALL
HANGER STRAP
(AROUND VAPOR
TUBE ONLY)
JOIST
1” (25.4 mm) MIN.
SUSPENSION
A94026
Fig. 1 -- Piping Installation
The outdoor unit contains system refrigerant charge for operation
with ARI rated indoor unit when connected by 15 ft. (4.57 m) of
field--supplied or factory accessory tubing. For proper unit
operation, check refrigerant charge using charging information
located on control box cover and/or in the Check Charge section of
this instruction.
IMPORTANT: Maximum liquid--line size is 3/8--in. OD for all
residential applications including long line.
IMPORTANT: Always install the factory--supplied liquid--line
filter drier. If replacing the filter drier, refer to Product Data Digest
for appropriate part number. Obtain replacement filter driers from
your distributor or branch.
Zobrazit stránku 0
1 2 3 4 5 6 7 8 9 10

Shrnutí obsahu

Strany 1 - Installation Instructions

127ALegacyt Line Air Conditionerwith Puronr Refrigerant1--1/2 To 5 Nominal Tons (Sizes 018 to 060)Installation InstructionsSAFETY CONSIDERATIONSImprop

Strany 2 - INSTALLATION

10Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.E2

Strany 3

2INSTALLATIONCheck Equipment and Job SiteUNPACK UNITMove to final location. Remove carton taking care not to damageunit.Inspect EquipmentFile claim wi

Strany 4 - CompressorCrankcaseHeater

3Outdoor Unit Connected to Factory Approved IndoorUnitOutdoor unit contains correct system refrigerant charge foroperation with factory approved ARI r

Strany 5 - OF OPERATION

4Table 2 – Accessory UsageACCESSORYREQUIRED FOR LONG LINEAPPLICATIONS*REQUIRED FORSEA COASTAPPLICATIONS(Within 2 miles/3.22 km)Ball Bearing Fan Motor

Strany 6 - TROUBLESHOOTING

5Airflow Selection for Variable Speed FurnacesThe variable speed furnaces provide blower operation to match thecapacities of the compressor during hig

Strany 7 - MAJOR COMPONENTS

6Check ChargeThe 127A units may be charged in high-- or low--stage compressoroperation. Factory charge amount and desired subcooling areshown on unit

Strany 8 - HUMIDFIER

7MAJOR COMPONENTS2--Stage CompressorThe 2--stage compressor contains motor windings that provide2--pole (3500 RPM) operation.Compressor Internal Relie

Strany 9

8A09276 A09277RVS/Heat Stage 2 O/W2/BHeat Stage 1 W/W1Compressor Low Y1Compressor High Y/Y2Fan G24VAC Hot Heating Rh24VAC Hot Cooling RcDry Contact 1

Strany 10 - Catalog No. II127

9PURONR (R--410A) REFRIGERANT QUICK REFERENCE GUIDES Puron refrigerant operates at 50--70 percent higher pressures than R--22. Be sure that servicing