Residential H&V - 60Hz R22
Rev.: 20 July, 2009B
Bryant: Whatever It Takes.
CAUTION: Indicates a potentially hazardous situation or an
unsafe practice, which if not avoided could result in minor or
moderate injury or product or property damage.
NOTICE: Noti cation of installation, operation or
maintenance information, which is important, but which is
not hazard-related.
Model Nomenclature: General Overview For All H & V Series
NOTE: Above model nomenclature is a general reference. Consult individual speci cation sections for detailed information.
WARNING! All refrigerant discharged from this unit must be
recovered WITHOUT EXCEPTION. Technicians must follow
industry accepted guidelines and all local, state, and federal
statutes for the recovery and disposal of refrigerants. If a
compressor is removed from this unit, refrigerant circuit
oil will remain in the compressor. To avoid leakage of
compressor oil, refrigerant lines of the compressor must be
sealed after it is removed.
CAUTION!
To avoid equipment damage, DO NOT use
these units as a source of heating or cooling during the
construction process. The mechanical components and
lters will quickly become clogged with construction dirt
and debris, which may cause system damage.
WARNING!
WARNING!
WARNING!
CAUTION!
Safety
Warnings, cautions and notices appear throughout this
manual. Read these items carefully before attempting any
installation, service or troubleshooting of the equipment.
DANGER: Indicates an immediate hazardous situation, which
if not avoided will result in death or serious injury. DANGER
labels on unit access panels must be observed.
WARNING: Indicates a potentially hazardous situation, which
if not avoided could result in death or serious injury.
Rev.: 17 Jul
y
, 2009B
NOTE: Some options/configurations not available on all series. Please consult Specification Catalogs for model specific options.
C = CXM
BACK
RIGHT
LEFT
LEFT
E
S
DISCHARGEOPTION
HORIZONTAL
RETURN
LEFT
BACK
Z
B
RIGHT
RIGHT
RIGHT
LEFT
R
L
DOWN
DOWN
RETURN
VERTICAL DOWNFLOW
OPTION DISCHARGE
048
072
060
036
042
030
YC = GT-G SINGLE-STAGE R22 REFRIG
024
018
3 = 208V, 230V/1PH/60Hz
CONTROLS:
HEAT EXCHANGER OPTIONS:
SIZE:
AIR FLOW CONFIGURATION - PSC:
VOLTAGE:
REVISION LEVEL:
PACKAGING:
1211109
13A
86754
C04
DISCHARGE
1 = SINGLE PACK, DOMESTIC
321
YEV05
OPTION
UNIT TYPE:
VERTICAL UPFLOW
RETURN
TOP
TOP
L
R
LEFT
RIGHT
0 = CURRENT REVISION
2
L
0
BACK
RIGHT
LEFT
LEFT
Y
W
DISCHARGEOPTION
HORIZONTAL
50YD/50YE ONLY*
RETURN
LEFT
BACK
N
P
RIGHT
RIGHT
RIGHT
LEFT
K
J
DOWN
DOWN
RETURN
VERTICAL DOWNFLOW
50YD/50YE ONLY*
OPTION DISCHARGE
AIR FLOW CONFIGURATION - ECM:
DISCHARGEOPTION
VERTICAL UPFLOW 50YD/50YE ONLY*
RETURN
TOP
TOP
J
K
LEFT
RIGHT
MOTOR
PSC
PSC
PSC
PSC
PSC
PSC
PSC
PSC
MOTOR
MOTOR
MOTOR
MOTOR
MOTOR
ECM
ECM
ECM
ECM
ECM
ECM
ECM
ECM
D = VERTICAL DOWNFLOW
H = HORIZONTAL
V = VERTICAL UPFLOW
CONFIGURATION:
E = CXM + ECM
USE PSC CONFIGURATION FOR 50YC SERIES AND SELECT CONTROL OPTION "E"
STANDARD
COATED AIR COIL
COPPER CUPRO-NICKEL
A
B
J
K
W/HOT WATER GENERATOR
RF
WHOLE HOUSE DEHUMIDIFICATION
LM
WHOLE HOUSE DEHUMIDIFICATION
W/HOT WATER GENERATOR
WARNING! Verify refrigerant type before proceeding.
Units are shipped with R-22 and R-407c refrigerants. The
unit label will indicate which refrigerant is provided. The
Puron
®
Application and Service Manual should be read
and understood before attempting to service refrigerant
circuits with R-407c.
WARNING! To avoid the release of refrigerant into the
atmosphere, the refrigerant circuit of this unit must be
serviced only by technicians who meet local, state, and
federal pro ciency requirements.