AC/HP Control should NOT be mounted:
S Close to a window, on an outside wall, or next to a door leading to the
outside.
S Exposed to direct light or heat from a lamp, sun, fireplace, or other
temperature--radiating objects which could cause a false reading.
S Close to or in direct airflow from supply registers and return--air regis-
ters.
S In areas with poor air circulation, such as behind a door or in an al-
cove.
Installer should determine whether control will be installed as single-- piece or
two--piece. In single--piece configuration, as many as 14 wires may need to run
to wall mounting location for connection to the control. In two--piece
configuration, the Display Module and Equipment Control Module are
connected by two wires.
Install AC/HP Control
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury or
death.
Before installing AC/HP Control, turn off all power to
equipment. There may be more than 1 power disconnect.
!
WARNING