CLEARANCE TO COMBUSTIBLES
UNIT APPLICATION L O W --- B O Y
SIDES
Furnace 1
Supply Plenum and Warm---Air Duct Within 6
Ft of Furnace
1
BACK Service Clearance 19
TOP
Furnace Casing or Plenum 2
Horizontal Warm--- Air Duct Within 6 Ft of
Furnace
2
BOTTOM* 0
FLUE PIPE
Horizontally or Below Pipe 4
Vertically Above Pipe 9
FRONT 8
*Floor may be combustible.
NOTE: Adequate service clearance should be provided over and above these dimensions as required.
PHYSICAL DATA
UNIT SIZE 036105 060120
INPUT (BTUH) 70,000 91,000 105,000 119,000 140,000 154,000
HEATING CAPACITY* 57,000 74,000 85,000 97,000 115,000 126,000
NOZZLE 0.40 --- 70A 0.50 --- 70W 0.65 --- 70W 0.75 --- 70B 0.85 --- 70W 1.00 --- 70W
FIRING RATE (GPH){ 0.50 0.65 0.75 0.85 1.00 1.10
AFUE% 80.5 80.5 80.5 80.0 80.0 80.0
OIL PUMP STAGES/PRESSURE
(PSIG)
1/160 1/170 1/135 1/130 1/140 1/125
HEATING TEMP RISE _F 55--- 85 55--- 85 55--- 85 55--- 85 55--- 85 55--- 85
COOLING CFM @ 0.5---IN. WC
STATIC PRESSURE
1250 1250 1250 1865 1865 1865
HEATING CFM @ 0.2---IN. WC
STATIC PRESSURE
840 1130 1425 1555 1890 2080
RECOMMENDED HEATING
BLOWER SPEED
M e d --- L o w M e d --- H i g h High M e d --- L o w M e d --- L o w High
SHIPPING WEIGHT (LB) 235 235 235 260 260 260
BURNER MODEL (3450 RPM) RIELLO
4 0 --- F 3
RIELLO
4 0 --- F 3
RIELLO
4 0 --- F 3
RIELLO
4 0 --- F 5
RIELLO
4 0 --- F 5
RIELLO
4 0 --- F 5
* Capacity and AFUE in accordance with U.S. Government DOE test procedures.