7. Remove the knockout in the lower
right corner of the external connection
box. From the rear of the connection
box, feed wires & 4-pin plug into box.
Slip the lock nut over the wires and
plug and tighten securely onto conduit
coupling. Match and connect wires by
color to lugs with existing wires. Snap
together the 4-pin connector. Loosen
the nut from the grounding lug and
attach ground wire (green) from the
conduit. Reinstall the nut and tighten.
Mount external connection box over
pre-drilled hole. Seal around the
conduit with insulation and silicone
caulk.
8. Install the automatic transfer switch
within 1' of your main electrical
distribution panel. Secure excess
conduit to walls and/or ceiling.
Switch off all circuit breakers
in the emergency load center.
9. In this step you will be relocating
circuits to be powered by the
generator from your main panel to
the emergency load center. After
removing the proper size knockout,
remove the threaded lock nut from
connector and feed all wires from 2’
conduit into your main electrical
distribution panel. Slip the lock nut
over wires from the inside of the
main panel and tighten onto
connector securely.
GROUND SCREW
KNOCK
OUT
1’
The outer diameter of
the threaded end is:
15/16” (7 & 12 kW) or
1-3/8” (15 kW)