—15—
PH13
HEAT PUMP HEATING PERFORMANCE Continued
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
–3 7 172737475767
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
EDB CFM Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW† Total Integ* kW†
PH13NR060-C Outdoor Section With PF1MNC061 Indoor Section
65
1750 19.21 17.67 3.07 24.56 22.57 3.28 30.59 27.89 3.50 37.63 33.42 3.74 46.04 41.90 4.03 55.76 55.76 4.35 66.07 66.07 4.62 77.07 77.07 4.99
2000 19.51 17.95 3.11 24.89 22.87 3.30 30.95 28.22 3.51 38.11 33.84 3.74 46.63 42.44 4.03 55.94 55.94 4.26 65.71 65.71 4.55 72.45 72.45 4.76
2250 19.79 18.21 3.15 25.19 23.15 3.34 31.27 28.51 3.54 38.52 34.21 3.77 47.03 42.79 4.02 55.81 55.81 4.24 65.23 65.23 4.52 67.81 67.81 4.61
70
1750 18.73 17.23 3.19 24.14 22.18 3.42 30.20 27.54 3.66 37.10 32.95 3.91 45.43 41.34 4.21 55.00 55.00 4.55 65.73 65.73 4.85 76.87 76.87 5.24
2000 19.04 17.52 3.23 24.47 22.49 3.45 30.56 27.87 3.67 37.56 33.36 3.91 45.98 41.84 4.20 55.61 55.61 4.51 65.54 65.54 4.77 74.11 74.11 5.06
2250 19.33 17.78 3.27 24.78 22.77 3.49 30.89 28.16 3.70 37.98 33.73 3.93 46.44 42.26 4.21 55.63 55.63 4.45 65.18 65.18 4.74 70.25 70.25 4.91
75
1750 18.20 16.75 3.31 23.67 21.75 3.56 29.78 27.15 3.82 36.61 32.52 4.09 44.75 40.72 4.40 54.30 54.30 4.76 65.26 65.26 5.12 76.55 76.55 5.50
2000 18.52 17.04 3.35 24.02 22.07 3.59 30.15 27.49 3.83 37.03 32.89 4.09 45.32 41.24 4.38 54.94 54.94 4.72 65.28 65.28 5.00 76.10 76.10 5.38
2250 18.81 17.31 3.40 24.33 22.36 3.63 30.48 27.79 3.86 37.42 33.24 4.10 45.81 41.68 4.39 55.30 55.30 4.69 65.04 65.04 4.96 72.44 72.44 5.22
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Unit
Size
Heating
Indoor
Section
Unit
Size
Heating
Capacity Power Capacity Power
PF1MNC 061 1.00 1.00 — — — —
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* The Btuh heating capacity values shown are net ‘‘integrated’’ values from which the defrost effect has been subtracted. The Btuh heating from supplement
heaters should be added to those values to obtain total system capacity.
† The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to
obtain total system kilowatts.
EDB = Entering Dry Bulb
SYSTEM DESIGN
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
2. Minimum outdoor operating air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature for cooling mode is 115°F (46.1°C).
4. Minimum outdoor operating air temperature for heating mode is –30°F (–34.4°C).
5. Maximum outdoor operating air temperature for heating mode is 66°F (18.9°C).
6. For reliable operation, unit should be level in all horizontal planes.
7. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 60 ft, indoor coil below = 200 ft.
8. For interconnecting refrigerant tube lengths greater than 80 ft horizontal, or 20 ft vertical differential, consult Long-Line Application Guideline
available from equipment distributor.
9. If ANY refrigerant tubing is buried, provide a minimum 6-in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to
36-in. may be buried without further considerations.
10. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
11. Mixmatches of indoor coil capacity more than 1 size larger than outdoor unit capacity may result in inadequate indoor comfort.